Serial Commands
Diagnostics
High Temperature Threshold
Low Temperature Threshold
Counts (Read-only)
Hours Since Reset (Read-only)
Service Message
Laser Current Warning Message
User-Defined Name
High Temperature Threshold
Serial Cmd:
<K402,status,message>
Default:
0 = Disabled
Options:
0 = Disabled
Message
Serial Cmd:
<K402,status,message>
Default:
HIGH_TEMP
Options:
Any valid ASCII string up to 128 characters
Low Temperature Threshold
Serial Cmd:
<K403,status,message>
Default:
0 = Disabled
Options:
0 = Disabled
Message
Serial Cmd:
<K403,status,message>
Default:
LOW_TEMP
Options:
Any valid ASCII string up to 128 characters
Counts (Read-only)
Power-On
Serial Cmd:
<K406,power-on,resets,power-on saves,power-on flash saves>
16-bit counter that increments on scanner power-on.
Resets
Serial Cmd:
<K406,power-on,resets,power-on saves,power-on flash saves>
16-bit counter that increments on scanner reset. Value is reset on power-on.
A-68
<K402,status,message>
<K403,status,message>
<K406> (returns: power-on,resets, power-on saves,custom default
saves)
<K407> (returns: hours,minutes)
<K409,status,service message, threshold,resolution>
<K411,laser high status,laser high message,laser low status,
laser low message>
<K412,user-defined name>
1 = Enabled
1 = Enabled