Matchcode
Match Start Position
Match Start Position is useful in defining specific portions of a symbol for comparison. For
example, if a symbol contains a part number, manufacturing date, and lot code info, but only the
part number information is needed, set the scanner to sort only the part number and to
ignore the other characters.
Match Start Position determines the portions of symbols that will be matched by defining
the first character in the symbol (from left to right) that will be compared with those of the
master symbol, when
For example, if Match Start Position is set to 3, the first 2 characters read in the symbol
will be ignored and only the 3rd and subsequent characters to the right will be compared,
up to the number of characters specified by Match Length.
Note: Match Start Position must be set to 1 or greater to enable this feature. A 0 setting
will disable this feature.
Match Length
Example: If Match Length is set to 6 in a 10-character symbol, and Match Start Position
is set to 2, only the 2nd through 7th characters (from left to right) will be compared.
Defines the length of the character string that will be compared with that of the master
symbol when Match Start Position is set to 1 or greater. When Match Start Position is
set to 0, no comparison will occur.
5-170
Matchcode Type
is set to Enabled or Sequential.