Calibration Options

Calibration Options specifies the operation of the calibration feature. The default configuration
is set up to perform calibration on Gain, Focus and Symbol Type.
Video
When set to Calibrate, there will be an attempt to change Video settings (Gain and
Tracking). Video settings include Gain and Tracking.
Scan Speed
When set to Calibrate, there will be an attempt to change Scan Speed. If a better read
rate at a different speed is found, the new speed will be the calibration result for Scan Speed.
Laser Power
When set to Calibrate, there will be an attempt to change Laser Power. If a better read
rate at a higher power is found, or if the same read rate at a lower power is found, the new
power level will be the calibration result for Laser Power.
5-127
QX-870 Industrial Raster Scanner User's Manual