Microscan N2210WZ Owner's Manual page 317

Industrial raster scanner
Table of Contents

Advertisement

Serial Trigger Character (Delimited)
Serial Cmd:
<K201,serial trigger
Default:
Space (0x20)
Options:
Any 7-bit ASCII character
External Trigger State
Serial Cmd:
<K202,active
Default:
1 = Positive
Options:
0 = Negative
End of Read Cycle
End of Read Cycle Mode
Serial Cmd:
<K220,end of read
Default:
0 = Timeout
Options:
0 = Timeout
1 = New Trigger
2 = Timeout or New Trigger
3 = Last Frame
4 = Last Frame or New Trigger
Read Cycle Timeout
Serial Cmd:
<K220,end of read
Default:
100 (x10 ms = 1 second)
Options:
1 to 65535
Decodes Before Output
Decodes Before Output
Serial Cmd:
<K221,decodes before
Default:
1
Options:
1 to 255
Mode
Serial Cmd:
<K221,decodes before output,mode>
Default:
0 = Non-Consecutive
Options:
0 = Non-Consecutive
Multisymbol
Number of Symbols
Serial Cmd:
<K222,number of
Default:
1
Options:
1 to 100
QX-870 Industrial Raster Scanner User's Manual
character>
state>
1 = Positive
cycle,read cycle timeout>
cycle,read cycle
output,mode>
1 = Consecutive
symbols,multisymbol separator>
timeout>
Appendices
A-31