Microscan N2210WZ Owner's Manual page 153

Industrial raster scanner
Table of Contents

Advertisement

Scanner Parameters
Pharmacode
Used mostly in pharmaceutical packaging.
Encodes up to five different numbers, each with its own color, which may be entered in
decimal or "binary" format with a 1 represented by a thick bar and a 0 represented by a
thin bar. Bar width is independent of height.
In decimal format, each part can be up to 999,999.
In binary format, each input can have up to 19 ones and zeros.
Important: When Pharmacode is enabled, other linear symbologies will not decode properly.
Disable Pharmacode before reading other linear symbologies.
Fixed Symbol Length Status
When enabled, the scanner will check the symbol length against the symbol length field. If
disabled, any length will be considered valid.
Fixed Symbol Length
Specifies the exact number of bars that must be present for the scanner to recognize and
decode the Pharmacode symbol.
Minimum Bars
Sets the minimum number of bars that a Pharmacode symbol must have to be considered valid.
Note: The minimum allowed bar count is 4.
5-87