Preamble Characters
Serial Cmd:
<K141,status,preamble
Default:
CR (0x0D)
Options:
1 – 4 ASCII characters
Postamble
Postamble Status
Serial Cmd:
<K142,status,postamble character(s)>
Default:
1 = Enabled
Options:
0 = Disabled
Postamble Characters
Serial Cmd:
<K142,status,postamble
Default:
CR LF (0x0D 0x0A)
Options:
1 – 4 ASCII characters
Response Timeout
Serial Cmd:
<K143,response
Default:
5 (x10 ms = 50)
Options:
0 to 255 (x10 ms)
LRC Status
Serial Cmd:
<K145,status>
Default:
0 = Disabled
Options:
0 = Disabled
ACK/NAK Options
Serial Cmd:
<K147,RES,REQ,STX,ETX,ACK,NAK>
RES-NAK Defaults
RES: (Reset)
REQ: (Request)
STX: (Start of Text)
ETX: (End of Text)
ACK: (Acknowledge)
NAK: (Negative Acknowledge)
QX-870 Industrial Raster Scanner User's Manual
character(s)>
1 = Enabled
character(s)>
timeout>
1 = Enabled
00 (disabled)
00 (disabled)
00 (disabled)
00 (disabled)
06
15