E2: Sound Speed Error

E3: Velocity Range

E4: Signal Quality

E5: Amplitude Error

6-2
Problem: The sound speed exceeds the limits programmed in the
Error Limits option of the User Program.
Cause:
The error may be caused by incorrect programming, poor
flow conditions or poor transducer orientation.
Action:
Compare the measured sound speed to tabulated nominal
values for the process fluid and correct any programming
errors. Refer to the sections on Fluid and Pipe Problems
(page 6-6) and on Transducer Problems (page 6-8) to
correct any problems.
Problem: The velocity exceeds the limits programmed in the Error
Limits option of the User Program.
Cause:
This error may be caused by the entry of improper
programming data or by poor flow conditions and/or
excessive turbulence.
Action:
Make sure the actual flow rate is within the programmed
limits. Also, check the value entered into the Error Limits
option, as described on page 2-18. Refer to the sections
on Fluid and Pipe Problems (page 6-6) and on
Transducer Problems (page 6-8) to correct any problems.
Problem: The signal quality is outside the limits programmed in the
Error Limits option of the User Program.
Cause:
The peak of the upstream or downstream correlation
signals has fallen below the correlation peak limit, as set
in the Error Limits option on page 2-18. This may be
caused by a flowcell or electrical problem.
Action:
Check for sources of electrical interference and verify the
integrity of the electronics console by temporarily
substituting a test flowcell that is known to be good.
Check the transducers and relocate them, if necessary.
Problem: The signal amplitude exceeds the limits programmed in
the Error Limits option of the User Program.
Cause:
Solid or gas particulates may be present in the flowcell.
The error could also be caused by poor coupling for
clamp-on transducers.
Action:
Refer to the section on Fluid and Pipe Problems (page
6-6) to correct any flowcell problems.