Entering the Pipe
Material (cont.)
Programming Site Data
.
Table 2-1: Preprogrammed Pipe Materials
Pipe Material Category
Al - Aluminum
Brass
Cu - Copper
CuNi - Copper/Nickel
Glass
Gold
Inconel
Iron
Monel
Nickel
Plastic
Steel
Tin
Titanium
Tungsten
Zinc
4. The next required parameter is either the outside diameter (OD) or
the circumference (OD x
press [ENT]. For either measurement, enter the desired value and
press [ENT].
Note: Obtain the required information by measuring either the pipe
outside diameter (OD) or circumference at the transducer
installation site. The data may also be obtained from standard
pipe size tables found in Sound Speeds and Pipe Size Data
(914-004).
5. The meter also requires the Wall Thickness (WT). Scroll to the WT
option, and press [ENT]. Use the arrow keys to enter the known
thickness, and press [ENT].
Note: To obtain an accurate pipe wall thickness measurement, use
an ultrasonic thickness gauge.
Specific Material
Rolled or None
None
Annealed, Rolled or None
70% Cu 30% Ni or 90% Cu 10% Ni
Pyrex, Flint, or Crown
Hard-drawn
None
Armco, Ductile, Cast, Electrolytic
None
None
Nylon, Polyethylene, Polyproplene,
PVC (CPVC), or Acrylic
Carbon Steel, Mild or Stainless Steel
Rolled
None
Annealed, Carbide, Drawn
Rolled
π).
Scroll to the measured parameter and