D.
ELECTRICAL INSTALLATION
1.
Refer to the nameplate on the front of the appliance. Verify the ELECTRICAL SERVICE
POWER. Voltage and phase must match the nameplate specifications, and available electrical
service amperage must meet or exceed the specifications listed on page 1.
Wiring must be no less than 4 AWG solid copper wire, rated for at least 90ºC.
NOTE: Wire gauge, insulation type and temperature rating , as well as type, size and
construction of conduit, must meet or exceed applicable specifications of local codes and
of the National Electrical Code.
2.
This appliance is equipped with a Hubble™ L430P9 plug, which must be plugged into a matching
Hubble™ L430R9 receptacle. The ground lug of the receptacle must be connected to a suitable
building ground.
4.
The appliance is shipped from the factory wired for 3-phase (3ø) electrical service.
IMPORTANT: This appliance is not approved for 1ø operation. Conversion of this appliance to
single-phase operation will void the warranty.
ELECTRICAL SHOCK HAZARD
ELECTRICAL CONNECTIONS MUST BE MADE BY A
LICENSED ELECTRICIAN
Electrical shock will cause death or serious injury.