Never pull out the module without pull the handle or the push bolts on the module. Direct pull
out the module with violent could damage the module and SFP module slot of the Managed
Switch.
2.2.4 Connecting DC Power Supply – SGSW-24040R / 24240R
The SGSW-24040R supports -48VDC power input, connect the power cable to the switch at the input terminal block.
1.
The size of the two screws in the terminal block is M3.5.
2.
The terminals are marked "-48V", "FG".
3.
Loosen the two screws so you can slide the DC cable beneath it. Insert the DC cable into the connector first, and screw it
down tight.
4.
Connect the power cable to the DC power supply. After power up or reset, the Managed Switch performs a cold start
procedure.
Figure 2-19 Pull out the SFP transceiver
Figure 2-20 -48VDC connector
27