3.1 Terminal Block Connector Pinout
To install the 3-pin Terminal Block Connector on the Wall-mount Managed
Switch, simply follow the following steps:
Step 1: Insert positive DC power wire into V+, negative DC power wire into
V-, and grounding wire into Ground.
Step 2: Tighten the wire-clamp screws for preventing the wires from
loosening and plug into the Wall-mount Managed switch.
1. The wire gauge should be in the range from 12 to 24 AWG
2. The device must be grounded.
3.2 DC Power Jack
The WGS-804HPT/WGS-4215 PoE models requires DC 48V~54V power input,
and the WGS-4215-8T/WGS-4215-8T2S requires DC 12~48V power input.
Should you have the issue of power connection, please contact your local sales
representative.
2.1mm
DC receptacle is 2.1mm wide that conforms to the WGS-4215 series
2.1mm DC jack's central post. Do not install any improper power
adaptor.
Ground
V
-
V+
DC Receptacle 2.1mm
7