Switching Operations between a Communications Option Card and Control Cir-
cuit Terminals
You can switch frequency reference input between the Communications Option Card and the control circuit
terminals. Set one of the parameters H1-01 to H1-05 (multi-function contact input terminal S3 to S7 function
selection) to 2 (Option/Inverter selection) to enable switching reference input using the terminal ON/OFF sta-
tus when the Inverter is stopped.
Setting Precautions
To switch command inputs between the Communications Option Card and the control circuit terminals, set the
following parameters.
Set b1-01 (Reference Selection) to 1 (Control circuit terminal [analog input])
Set b1-02 (Operation Method Selection to 1 (Control circuit terminal [sequence inputs])
Set one of the parameters H1-01 to H1-05 (multi-function contact input terminal S3 to S7 function selec-
tion) to 2 (Option/Inverter selection).
Terminal Status
OFF
ON
Jog Frequency Operation without Forward and Reverse Commands (FJOG/
RJOG)
The FJOG/RJOG command functions operate the Inverter using jog frequencies by using the terminal ON/
OFF operation. When using the FJOG/RJOG commands, there is no need to input the run command.
To use this function, set one of the parameters H1-01 to H1-05 (multi-function contact input terminal S3 to S7
function selection) to 12 (FJOG command) or 13 (RJOG command).
Related Parameters
Param-
eter-
Number
d1-17
Multi-Function Contact Inputs (H1-01 to H1-05)
Set
Value
12
FJOG command (ON: Forward run at jog frequency d1-17)
13
RJOG command (ON: Reverse run at jog frequency d1-17)
-48
6
Inverter
(Can be operated from frequency reference or control circuit terminal from analog input termi-
nal.)
Communications Option Card
(Frequency reference and run command are enabled from communications Option Card.)
Name
LCD Display
Jog frequency reference
The frequency reference when the jog frequency reference
selection, FJOG command or RJOG command is ON.
Jog Reference
Frequency Reference and Run Command Selection
Description
Function
Change
Setting
Factory
during
Access
Range
Setting
Opera-
Level
tion
0 to
6.00 Hz
Yes
Q
120.00

Advertisement