Single-Phase Input Ac Reactor; Three-Phase Input Ac Reactor - Omron 3G3MX2 User Manual

Mx2 series 200 v class three-phase input 0.1 to 15 kw 200 v class single-phase input 0.1 to 2.2 kw 400 v class three-phase input 0.4 to 15 kw
Hide thumbs Also See for 3G3MX2:
Table of Contents

Advertisement

Component Descriptions
Voltage
Reference
AX-RAI02000070-DE
AX-RAI01700140-DE
200 V
AX-RAI01200200-DE
AX-RAI00630240-DE
Voltage
Reference
AX-RAI02800080-DE
AX-RAI00880200-DE
200 V
AX-RAI00350335-DE
AX-RAI00180670-DE
AX-RAI07700050-DE
AX-RAI03500100-DE
400 V
AX-RAI01300170-DE
AX-RAI00740335-DE
Fig. 1 (single-phase input AC reactor)
Dimensions (mm)
A
B
C
D
E
96
116
84
113
101
66
131
116
Fig. 2 (three-phase input AC reactor)
Dimensions (mm)
A
B2
C2
D
70
120
120
80
80
180
85
190
140
70
120
120
80
80
180
85
190
140
Power supply
Voltage
1-phase 200 VAC
3G3MX2-A2002/-A2004/-A2007
3G3MX2-A2015/-A2022/-A2037
3-phase 200 VAC
3G3MX2-A4004/-A4007/-A4015
3G3MX2-A4022/-A4030/-A4040
3-phase 400 VAC
Weight
Max. motor
kg
output kW
F
G
H
1.22
1.95
5
7.5
2
2.55
1.95
Weight
Max. motor
kg
output kW
E
F
52
1.78
5.5
62
2.35
55
6
5.5
52
1.78
5.5
2.35
62
2.50
55
6
5.5
AC reactor
MCCB
U
X
V
Y
W
Z
Inverter model
3G3MX2-AB002/-AB004
3G3MX2-AB007
3G3MX2-AB015
3G3MX2-AB022
3G3MX2-A2055/-A2075
3G3MX2-A2110/-A2150
3G3MX2-A4055/-A4075
3G3MX2-A4110/-A4150
Section 5-2
Current
Inductance
value A
mH
0.4
7.0
2.0
0.75
14.0
1.7
1.5
20.0
1.2
2.2
24.0
0.63
Current
Inductance
value A
mH
1.5
8.0
2.8
3.7
20.0
0.88
7.5
33.5
0.35
15
67.0
0.18
1.5
5.0
7.7
4.0
10.0
3.5
7.5
17.0
1.3
15
33.5
0.74
MX2
R/L1
S/L2
T/L3
DC reactor model
AX-RAI02000070-DE
AX-RAI01700140-DE
AX-RAI01200200-DE
AX-RAI00630240-DE
AX-RAI02800080-DE
AX-RAI00880200-DE
AX-RAI00350335-DE
AX-RAI00180670-DE
AX-RAI07700050-DE
AX-RAI03500100-DE
AX-RAI01300170-DE
AX-RAI00740335-DE
257

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents