5-1
Introduction
5-1-1
Introduction
Fro power suppl
Breaker,
MCCB or
GFI
AC reactor
(Input choke)
EMI filter
L1
L2
L3
+1
Inverter
+
RB
Braking
Resistor
P/+
GND
T1 T2 T3
RF noise
filter choke
AC reactor
(Output choke)
Motor
Ther al
switch
A motor control system will obviously include a motor and inverter, as well as
fuses for safety. If you are connecting a motor to the inverter on a test bench
just to get started, that's all you may need for now. But a fully developed sys-
tem can also have a variety of additional components. Some can be for noise
suppression, while others may enhance the inverter's braking performance.
The figure below shows a system with several possible optional components,
and the table gives part number information.
Name
AC reactor, input side
EMC filter (for CE)
DC reactor
Braking resistor
RF noise filter choke, output side
AC reactor, output side
DC link
choke
Inverter System Accessories
Part No. Series
AX-RAIxxxxxxxx-DE
AX-FIMxxxx-RE
AX-RCxxxxxxxx-RE
AX-REMxxxxxxx-IE
AX-FERxxxx-RE
AX-RAOxxxxxxxx-DE
SECTION 5
See
page
256
259
261
263
259
258
255