The web-based user interface explains what is retained by each reset. The following table
outlines configuration settings and files affected by the SIS command and rear panel resets.
In general, configuration settings and files can be:
Device Reset From:
SIS
Command
Factory
n/a
Firmware (one
power cycle)
Network (IP
n/a
settings) reset
E
Flash Reset
}
ZFFF
E
System reset
}
ZXXX
(Factory
defaults).
User files
and settings
Retained.
E
Reset device
}
ZY
settings and
delete user
files.
Retain IP
settings.
E
Absolute
}
ZQQQ
Reset:
settings,
files, and IP
settings.
NOTE: A browser refresh is required to see results of a reset.
Retained (not affected by the reset).
Reset to factory (the original factory firmware replaces the current).
Erased (the configuration settings or files are deleted).
Rear Panel
Web-
based User
Interface
Mode 1
n/a
(see note,
below)
Mode 4
n/a
n/a
n/a
n/a
Reset device
settings to
default, but
retain user
files and all
IP settings
n/a
Reset device
settings
to default,
delete user
files, retain
IP settings
Mode 5
Reset device
settings,
delete
internal user
files, and
Reset all IP
settings
Firmware User
Network
File
Shares
System
Factory
Retained Retained Retained Retained
Retained
Retained Reset
Retained
Erased
Retained Retained Retained
Retained
Retained Reset
Retained
Erased
Reset
Retained
Erased
Reset
SMD 101 • Reference Information
Device
Passwords IP
Config
Settings
Retained
Retained Retained
Reset
Retained
Reset
Retained
Retained
Reset
Reset
Retained
Reset
Reset
Reset
84