Local Administrative Options

Interface Control

Use the following procedure to set or change the interface control value.
1. When you select INT from the Craft Local Procedure Screen, the following text displays with
a prompt to use the Right and Left navigation arrows to select a setting:
Ethernet:
PC Ethernet:
Except for the 9610 which displays the actual value, the values shown are the text strings
associated with the current PHY1STAT on the Ethernet line and the current PHY2STAT
system value on the PC Ethernet line.
The PHY1STAT text strings are:
"Auto" when PHY1STAT = 1
"10Mbps half" when PHY1STAT = 2
"10Mbps full" when PHY1STAT = 3
"100Mbps half" when PHY1STAT = 4
"100Mbps full" when PHY1STAT = 5
"1000 Mbps full" when PHY1STAT = 6
The PHY2STAT text strings are:
"Disabled" when PHY2STAT = 0
"Auto" when PHY2STAT = 1
"10Mbps half" when PHY2STAT = 2
"10Mbps full" when PHY2STAT = 3
"100Mbps half" when PHY2STAT = 4
"100Mbps full" when PHY2STAT = 5
"1000 Mbps full" when PHY2STAT = 6
2. To change the Ethernet setting, press the Right navigation arrow to cycle through the
possible settings.
Depending on the current value, the next sequential text string is selected and displayed as
the setting. For example, if the current value is 10Mbps half (2), pressing the Right
navigation arrow changes the value to 10Mbps full (3). If the current value is 1000Mbps full
(6), pressing the Right navigation arrow changes the value to Auto (1).
3. To change the PC Ethernet setting, select that line and press the Right navigation arrow to
cycle through the possible settings.
4. Press Save to store the new setting(s) and redisplay the Craft Local Procedure screen.
44 9600 Series IP Telephones Release 3.0 Installation and Maintenance Guide