Set The 802.1X Operational Mode - Avaya one-X 9600 Series Installation And Maintenance Manual

Deskphone edition release 3.0
Hide thumbs Also See for one-X 9600 Series:
Table of Contents

Advertisement

Set the 802.1X Operational Mode

Use the following procedure to set or change the operational mode.
1. When you select 802.1X from the Craft Local Procedure Screen, the following text displays:
Supplicant:
Pass-thru:
where the Supplicant line is the text string associated with the current system value of
DOTIXSTAT (802.1X Supplicant Mode operation control), defined as:
"Disabled" if DOT1XSTAT = 0
"Unicast-only" if DOT1XSTAT = 1
"Unicast/multicast" if DOT1XSTAT = 2
and the Pass-thru line is a text string associated with the current system value of DOT1X
(802.1X Supplicant Mode)
"Enabled mode" if DOT1X = 0
"Enabled w/Logoff" if DOT1X = 1
"Disabled" if DOT1X = 2
2. Select (highlight) the line you want to change, then press Change.
3. Depending on which line you selected to change, the following text displays:
Current setting:
New Setting:
where, if you selected the Supplicant line, the setting is the text string associated with the
current system value of DOTIXSTAT, or if you selected the Pass-thru line, the setting is the
text string associated with the current system value of DOTIX.
4. To change the setting, press the Right (or Left) navigation arrow to cycle through the
applicable settings.
Depending on the current value, the next sequential text string is selected and displayed as
the New setting. For example when changing the Pass-thru mode, if the current value is
Pass-thru mode, pressing the Choice Selector displays P-t w/Logoff. If the current setting is
disabled, pressing the Choice Indicator changes the new setting to Pass-thru mode.
5. Press Save to store the new setting and redisplay the Craft Local Procedure screen.
Set the 802.1X Operational Mode
Issue 6 February 2009
37

Advertisement

Table of Contents
loading

Table of Contents