Magnum 6K8-Series Industrial Field Switch
face plate with 4 screws to complete the installation process for port module.
The front panel screen plate does not need any screws to hold on port module,
but need to place tightly and carefully while placing on LEDs.
Step 8. Once 6KPMV card have been installed (including faceplate and screen plate),
the chassis cover should be replaced. Make sure the chassis top cover is aligned
properly to the base before securely sliding the chassis base track inside the top
3.6.3
Removing 6KPM Cards
To properly remove a 6KPM card from the 6K8-Series Industrial Field Switch,
follow the 3 steps below.
Step 1.
Remove chassis cover
Step 2.
Remove retaining screws placed on top of the 6KPMV and Face Plate
Each 6KPMV module is
secured with nine retaining
screws #440x3/8. These screws
are used to secure a 6KPM
card in position (see Figure
3.6.3a). Remove the 9 screws
to take off the daughter module
and thereafter three standoffs
www GarrettCom com
.
See procedures in Section 3.6.1 above.
Caution: Be sure the power cord is unplugged.
.
Installation and User Guide 03/06)
cover properly as shown in
Fig 3.6.2h
sliding in the top cover
onto the chassis base
track
37