Table 10
Fault Symptom Codes (continued)
FSC
Message
701B
Invalid L-drive number to convert
(Attempted to send a command to a
drive, but the logical drive number is out
of range.)
701C
Invalid P-drive number to convert
(Attempted to send a command to a
drive, but the physical drive number is out
of range.)
701D
Invalid mod number to convert
(Attempted to send a command to a drive
in a remote module, but the module
number is out of range.)
701E
Unknown drive type
(Attempted to show detailed drive status
of a drive whose type is unknown.)
701F
The SCSI response was not expected
(The command response from the SCSI
task in a remote module was
unexpected.)
7020
The Flash response was not expected
(The command response from the Flash
task in a remote module was
unexpected.)
130
Troubleshooting
ERP
Press the Enter button clear the
message.
Cycle power to the library or reboot
using the GUI touch screen.
Ensure the drive shows good status
through the drive status window.
Press the Enter button clear the
message.
Cycle power to the library.
Ensure the drive shows good status
through the drive status window.
Press the Enter button clear the
message.
Cycle power to the library or reboot
using the GUI touch screen.
Press the Enter button clear the
message.
Cycle power to the library or reboot
using the GUI touch screen.
Ensure the drive shows good status
through the drive status window.
Press the Enter button clear the
message.
Cycle power to the library or reboot
using the GUI touch screen.
Ensure the drive shows good status
through the drive status window.
Press the Enter button clear the
message.
Cycle power to the library or reboot
using the GUI touch screen.
Ensure the drive shows good status
through the drive status window.