Table 10
Fault Symptom Codes (continued)
FSC
Message
7013
Control Com Unidentified
(During a hot swap, a command response
from the control task could not be
associated with any outstanding
command.)
7014
Drive status update failed
(The drive task indicates that a request to
determine the current state of a drive
failed. Reason unknown.)
7015
Loader command execution failed
(The loader task indicates that a
command has failed to complete
successfully.)
7016
Sequential command execution failed
(The sequential task indicates that a
command has failed to complete
successfully.)
7017
Destination Xchg for msg. was Null
(Attempted to send a message to a task,
but the argument exchange pointer was
NULL.)
7018
Bad src mod in peg msg
(A message was received from a remote
module, but the module number was out
of range.)
7019
Peg message wrapping a Null msg. ptr.
(A peg message has a pointer to NULL.)
701A
Xchg conversion failed
(Attempted to determine the module
number containing the task that is
returning a command response failed.)
ERP
Press the Enter button clear the
•
message.
•
Cycle power to the library or reboot
using the GUI touch screen.
•
Ensure the drive shows good status
through the drive status window.
Press the Enter button clear the
•
message.
•
Cycle power to the library or reboot
using the GUI touch screen.
•
Ensure the drive shows good status
through the drive status window.
Press the Enter button clear the
•
message.
•
Cycle power to the library or reboot
using the GUI touch screen.
Press the Enter button clear the
•
message.
•
Cycle power to the library or reboot
using the GUI touch screen.
Press the Enter button clear the
•
message.
•
Cycle power to the library or reboot
using the GUI touch screen.
Press the Enter button clear the
•
message.
•
Cycle power to the library or reboot
using the GUI touch screen.
•
Press the Enter button clear the
message.
•
Cycle power to the router.
•
Cycle power to all libraries in a stack, or
reboot using the GUI touch screen.
•
Press the Enter button clear the
message.
•
Cycle power to the library or reboot
using the GUI touch screen.
MSL6000 series tape library user guide 129