Table 10
Fault Symptom Codes (continued)
FSC
Message
3016
Drive Status Failure
3017
Drive In Flux Timeout
(Time-out waiting for drive to clear the full
status.)
3018
Drive Load Retry Failed
(SLTO drive fail to load, detected in drive
task.)
ERP
Press the Enter button to reboot.
Ensure the drive shows good status
through the drive status window.
Deactivate the drive using the GUI control
panel maintenance menu.
Reseat the drive.
Check cabling.
Load/unload a cartridge to the drive to
verify.
Check the tape cartridge used in the last
operation for damage.
Run the cartridge cycle diagnostic to
verify.
Press the Enter button to reboot.
Ensure the drive shows good status
through the drive status window.
Deactivate the drive using the GUI control
panel maintenance menu.
Reseat the drive.
Check cabling.
Load/unload a cartridge to the drive to
verify.
Run the cartridge cycle diagnostic to
verify.
Press the Enter button to reboot.
Ensure the drive shows good status
through the drive status window.
Deactivate the drive using the GUI control
panel maintenance menu.
Reseat the drive.
Check cabling.
Load/unload a cartridge to the drive to
verify.
Check the tape cartridge used int he last
operation for damage.
Run the cartridge cycle diagnostic to
verify.
MSL6000 series tape library user guide 111