Table 10
Fault Symptom Codes (continued)
FSC
Message
700C
Destination Xchg was Null
700D
Sending of a cmd failed
700E
Deactivating a drive that is not attached
(The control task indicates that a request
to deactivate a drive failed because the
drive is not attached.)
700F
Deactivation of a drive failed
(The control task indicates that a request
to deactivate a drive failed. Reason
unknown.)
7010
Drive removal failed
(The drive task indicates that a request to
power-down a drive failed. Reason
unknown.)
7012
Drive is Active failed
(The drive task indicates that a request to
determine if a drive is executing a host
command failed. Reason unknown.)
128
Troubleshooting
ERP
Press the Enter button to reboot.
•
•
Cycle power to the library or reboot
using the GUI touch screen.
•
Press the Enter button to reboot.
•
Cycle power to the library or reboot
using the GUI touch screen.
Press the Enter button clear the
•
message.
•
Cycle power to the library or reboot
using the GUI touch screen.
•
Ensure the drive shows good status
through the drive status window.
Reseat the drive.
•
•
Check cabling.
Press the Enter button clear the
•
message.
•
Cycle power to the library or reboot
using the GUI touch screen.
•
Ensure the drive shows good status
through the drive status window
•
Reseat the drive.
•
Check cabling.
Press the Enter button clear the
•
message.
•
Cycle power to the library or reboot
using the GUI touch screen.
•
Ensure the drive shows good status
through the drive status window.
Press the Enter button clear the
•
message.
•
Cycle power to the library or reboot
using the GUI touch screen.
•
Ensure the drive shows good status
through the drive status window.