Table 10
Fault Symptom Codes (continued)
FSC
Message
700C
Destination Xchg was Null
700D
Sending of a cmd failed
700E
Deactivating a drive that is not attached
(The control task indicates that a request
to deactivate a drive failed because the
drive is not attached.)
700F
Deactivation of a drive failed
(The control task indicates that a request
to deactivate a drive failed. Reason
unknown.)
7010
Drive removal failed
(The drive task indicates that a request to
power-down a drive failed. Reason
unknown.)
7012
Drive is Active failed
(The drive task indicates that a request to
determine if a drive is executing a host
command failed. Reason unknown.)
128
Troubleshooting
ERP
Press the Enter button to reboot.
Cycle power to the library or reboot
using the GUI touch screen.
Press the Enter button to reboot.
Cycle power to the library or reboot
using the GUI touch screen.
Press the Enter button clear the
message.
Cycle power to the library or reboot
using the GUI touch screen.
Ensure the drive shows good status
through the drive status window.
Reseat the drive.
Check cabling.
Press the Enter button clear the
message.
Cycle power to the library or reboot
using the GUI touch screen.
Ensure the drive shows good status
through the drive status window
Reseat the drive.
Check cabling.
Press the Enter button clear the
message.
Cycle power to the library or reboot
using the GUI touch screen.
Ensure the drive shows good status
through the drive status window.
Press the Enter button clear the
message.
Cycle power to the library or reboot
using the GUI touch screen.
Ensure the drive shows good status
through the drive status window.

Hide quick links: