HP MSL6000 Series User Manual page 107

Storageworks msl6000 series storage tape library
Hide thumbs Also See for MSL6000 Series:
Table of Contents

Advertisement

Table 10
Fault Symptom Codes (continued)
FSC
Message
2010
Ctl. Firmware Error
(Internal task processing error.
Unexpected event. SMX send or receive
error.)
2030
Drive Timeout Error
2080
Drive Code Update Command Error
(Update code from SCSI or from tape
failed.)
2081
Move Command Failure
(Move command from or to drive slot
failed. Detected by control task.)
2090
Open Mail Slot Fault
(Door open sensor time-out detected
when open door.)
2091
Open Left Door Fault
(Door open sensor time-out detected
when open door.)
ERP
Cycle power to the library or reboot
using the GUI touch screen.
Upgrade firmware if a newer revision
exists.
Check if the drive shows good status
through the drive status window.
Cycle power to the library or reboot
using the GUI touch screen.
Reseat drive.
Make sure that the firmware is the correct
file for this product.
Check if the drive shows good status
through the drive status window.
Cycle power to the library or reboot
using the GUI touch screen.
Attempt firmware upgrade again.
Press the Enter button to reboot.
Ensure the drive shows good status
through the drive status window.
Cycle power to the library or reboot
using the GUI touch screen.
Load/unload a cartridge to the drive to
verify.
Press the Enter button to clear the
message.
Cycle power to the library or reboot
using the GUI touch screen.
Run sensor test.
Make sure door(s) are closed.
Press the Enter button to clear the
message.
Cycle power to the library or reboot
using the GUI touch screen.
Run sensor test.
Make sure door(s) are closed.
MSL6000 series tape library user guide 107