Table 10
Fault Symptom Codes (continued)
FSC
Message
2092
Open Right Door Fault
(Door open sensor time-out detected
when open door.)
2093
Open Doors Fault
(Door open sensor time-out detected
when open door.)
2094
Open DLT Handle Fault
(Failed to open DLT handle.)
20a0
No IP Address Found
(SMC router failed to get an IP address.)
20a1
No IP Address Mode Fault
(SMC router failed to detect static or IP
address mode.)
20b0
Unknown Exchange For The Async
message
(Unexpected exchange detected when
process messages.)
108
Troubleshooting
ERP
Press the Enter button to clear the
message.
Cycle power to the library or reboot
using the GUI touch screen.
Run sensor test.
Make sure door(s) are closed.
Press the Enter button to clear the
message.
Cycle power to the library or reboot
using the GUI touch screen.
Run sensor test.
Make sure door(s) are closed.
Press Enter to clear the message.
Cycle power to the library or reboot by
using the LCD touch display
Make sure the drive shows good status
through the drive status window.
Press the Enter button to clear the
message.
Ensure network configuration options are
set correctly.
Cycle power to the library or reboot
using the GUI touch screen.
Press the Enter button to clear the
message.
Ensure network configuration options are
set correctly.
Cycle power to the library or reboot
using the GUI touch screen.
Press the Enter button to reboot.
Cycle power to the library or reboot
using the GUI touch screen. Wait 30
seconds to power up again.