SATEL
The installer can configure the control panel so that acknowledgement of receiving the
message by the user will:
 clear messaging other users;
 allow to get access to the INT-VG module voice menu.

10. Call answering and telephone control

The information below does not apply to the control panels to which the INT-VG
module is connected.
The call answering and telephone control functions are available to the users who have the
telephone code. These functions require that the DTMF dialing phone be used. The call
answering function allows to get information on the partition status (armed, disarmed). Owing
to the telephone control function, it is possible to control the R
using the telephone.

10.1 Answering phone calls

1. Establish connection with the control panel, using one of the following methods (consult
the installer to learn which method is supported by the control panel):
single call – call the telephone number of control panel. The control panel will answer the
call after the number of rings programmed by the installer.
double call – call the telephone number of control panel. Hang up after the number of
rings programmed by the installer. Call again within three minutes. The call will be
answered by the control panel immediately.
Establishing connection will be signaled by three short beeps.
2. Enter the telephone code on the telephone keypad. 4 short beeps and 1 long beep will
confirm that you have got access to the call answering function. If the entered code is
invalid, this will be signaled by the control panel by two long beeps.
If you make a mistake when entering the code, enter the 4 digits anyway, and when
the control panel signals that the code is wrong, enter the correct code.
After entering three wrong codes, the control panel will hang up.
In case of a single call, if:
 no code has been entered and the connection is terminated,
 an invalid code has been entered and the connection is terminated,
the control panel will answer no calls for the next few minutes. It enables e.g. a fax to
be connected after the control panel.
3. Within up to 15 seconds, enter the 2-digit partition number (e.g. 01, 07 or 15). The control
panel will inform you about the partition status by means of sound signals:
3 short beeps – partition disarmed;
4 short and 1 long beeps – partition armed.
If no key is pressed on the phone for 15 seconds, the control panel will hang up.
4. Upon pressing in turn the 0 and # keys on the telephone keypad, the control panel will
hang up.