The administrator defines whether the installer is to have access to the U
submenu (S
Masters – the submenu provides the following functions available to the installer:
New master – allows to create a new administrator.
Edit master – allows to edit the existing administrators.
Remove master – allows to remove the existing administrators.
Zone bypasses – the following functions are available in the submenu:
Inhibit – allows to temporarily bypass the zones (see: section Z
p. 29).
Isolate – allows to permanently bypass the zones (see: section P
(I
) p. 29).
SOLATE
If the G
RADE
available to the installer.
Set time – allows to program the control panel clock. The data are entered in the following
format:
time – hour:minute:second,
date – day:month:year.
System state – allows to view the troubles and, if the G
enabled by the installer, also the alarms and bypassed zones, as well as to check the
partition status.
Events – the submenu contains functions which allow to view the events saved to the control
panel memory (see: section E
Reset zones – running the function will result in a temporary deactivation of the
43. R
ESETABLE POWER SUPPLY
memory for detectors supplied from those outputs (e.g. fire detectors).
Clear latched outputs – allows to turn off some of the control panel outputs for which the
L
option is enabled, as well as the 9. DAY A
ATCH
and 116. I
NTERNAL SIREN
Fin.f.door open – restores the normal operating mode in all modules executing the access
control functions (in case of fire, the doors controlled by these modules may be
automatically unlocked).
Change options – the following functions are available in the submenu:
Keypad chime – turns on/off the chime signal in the keypad (signaling violations of
selected zones).
Outputs chime – allows to block the chime signal from selected partitions on the
11. C
type output.
HIME
Timers – allows to program parameters of the timers controlling the 120. T
outputs, and other timers, the editing of which is permitted by the installer.
Temperatures – allows to edit the temperature thresholds for 120. T
outputs.
Partition timers – allows to program the partition timers (see: P
PARTITION TIMER
No expanders tamper alarms – allows to temporarily disable the expansion module
tamper supervision. In case of any problems with the expansion modules, report the fact
to the installer.
Permanent service access – the option is available to the master user (administrator). If
enabled, the installer has permanent access to the alarm system, which, among other
.
option in the C
ERV
CAN EDIT
3 option has been enabled by the installer, the I
VENT LOG REVIEWING
type outputs, thus making it possible to reset the alarm
type outputs.
p. 31).
INTEGRA Plus
HANGE OPTIONS
p. 30).
submenu).
ONE BYPASSING
ERMANENT BYPASSING
function is only
SOLATE
3 global option has been
RADE
, 12. S
LARM
HERMOSTAT
HERMOSTAT
ROGRAMMING THE
17
SERS
(
)
INHIBIT
ILENT
ALARM
type
type