Before you start programming, please read carefully this manual in order to avoid mistakes that can lead to malfunction or even damage to the equipment. The SATEL's goal is to continually upgrade the quality of its products, which may result in alterations of their technical specifications and firmware. The current information on the introduced modifications is available on our website.
Page 3
Changes made to the firmware version 1.12 Option to hide the service mode using the H function. Service mode New zone type: O Zones UTPUTS GROUP New option: D 2&3 ELAY IN TYPE ARMING The R "T " option applies also to the System options ETURN TO MENU FROM MENU functions available in the C...
Programming SATEL CONTENTS General ..........................4 Programming options......................4 Keypad ........................4 2.1.1 Starting the service mode ....................4 2.1.2 Starting the service mode "from pins" ................5 2.1.3 Hiding the service mode....................5 2.1.4 Exiting the service mode ....................5 2.1.5 Service mode menu ....................... 5 2.1.6...
Page 5
SATEL INTEGRA Plus 5.2.1 Printout options ......................57 5.2.2 Printout contents ......................58 Other options ......................58 Arming options......................60 Times........................61 Service options and parameters ................61 Other parameters ....................61 Default user's authority level..................63 Programming the keypads....................63 Keypad parameters and options................
Programming SATEL 1. General This manual applies to the control panels of the INTEGRA Plus series: – INTEGRA 64 Plus – INTEGRA 128 Plus – INTEGRA 256 Plus 2. Programming options The control panel may be programmed: locally – LCD keypad;...
SATEL INTEGRA Plus 2.1.2 Starting the service mode "from pins" When entering the service mode in the normal way is not possible (the control panel does not support LCD keypads, does not accept the service code, etc.), you can use the emergency procedure, so-called, starting "from pins."...
Page 8
Programming SATEL GuardX ident. DloadX tel. No GuardX tel. No Block SM Block DWNL SM sounds Hide SM now Hide SM after Structure System Objects Edit object New object Delete object Partitions Settings [select partition by name] Type Dep. partitions Timers 1..32...
Page 9
SATEL INTEGRA Plus Settings [select device by name – see: p. 16] ABAX confirmat. INT-IT-wt.2cd. Rem. RX key fobs Copy RX keyfobs Rem. ABAX kfobs Copy ABAX kfobs Names [select device by type and address] DT1 short Tmp.alw.ld.DT1 DT2 short Tmp.alw.ld.DT2...
Page 10
Programming SATEL Bypasses Access control Troubles User functions System events Active rights Various options Grade3 Simple codes Notify of code Confirm with 1 Autoabort msg. SM -> menu Tests -> menu No AC-no blght Fast exp. bus No rest. mon.
Page 11
SATEL INTEGRA Plus PING tries Integrate key Zones Details [select zone by name] Sensitivity [x20ms] / Pulses time / Sensitiv. [ms] / Output Pulses count Type Entry delay / Alarm delay / Surveillan. time / Signal. delay / Bypass time / Expander number / Arming mode / Group / Exit time / Outputs group Max.viol.time / Max.opening t.
Page 12
Programming SATEL Zones Bypass on/off Test SIGNAL. OUTPUT [select zone] Names [select zone by number] Outputs Details [select output by name] Function Cut-off time Polarization + Pulsating Latch Timers control Timers 33..64 Arm - no ctrl. Off-delay tmr. Zones / Timers / Expanders / Outputs / Users / Doors / Voice mess. / Tel.
Page 13
SATEL INTEGRA Plus [select schedule by name] Names [select schedule by number] Monitoring Mon. TELEPHONE Mon. GPRS Mon. ETHM-1 Dont rep. rsts. Stations Advanced Long hsk.s1t1 Long hsk.s1t2 Long hsk.s2t1 Long hsk.s2t2 Long hsk. wait. Need ack.id.s1 Id. 6-chars s1 Source name s1 Partit.name s1...
Page 14
Programming SATEL Tel. 1 format Tel. 2 format IP address Port Key (MS) Key (GPRS) Key (ETHM) SIA-IP Coded Key (SIA-IP) Timestamp SIA-IP test Repetition cnt. Suspension time TELIM/SIA prefix Identifier n [n – identifier number] Identifier sys. Event assign.
Page 15
SATEL INTEGRA Plus Tel. settings [select telephone by name] Tel. number Type Rounds count Any code Code Assignment Zone alarms Synthesizer Pager message Telephones Zone tampers Synthesizer Pager message Telephones Panic alarms Synthesizer Pager message Telephones Fire alarms Synthesizer Pager message...
Page 16
Programming SATEL [select message] Pager types [select pager] Msg.abort in P. [select telephone by name] Msg.abort on T. [select telephone by name] SMS messaging SMS messaging Tel. names [select telephone by number] Tel. settings [select telephone by name] Tel.answ./ctrl. Voice answer.
Page 17
SATEL INTEGRA Plus Chime bps. zone Chime bps. time Quickarm part. Fin.exit time Entry time p. Exit time p. DateTime format Name (2nd row) LCD backlight Keys backlight Auto backlight Alarm messages Part. al.mess. Zone al.mess. Code + card Alarms...
Page 18
Programming SATEL Card close long Door to open Tamper in part. Z1 (n) in LCD [n – number of zone in the system] Z2 (n) in LCD [n – number of zone in the system] CA-64 PTSA Zones Partitions Alarms...
Page 19
SATEL INTEGRA Plus Entry time Exit time Auto-arm delay Hardw. signal Force arm Al. 3 unk .cards No autorst.3t. Tamper in part. INT-S / INT-SK / INT-SCR Lock feature Lock Lock function Relay ON time Relay type (only INT-S and INT-SK) Unauth.
Page 20
Programming SATEL Auto backlight No autorst.3t. Partition INT-SZ / INT-SZK Lock Lock function Relay ON time Relay type Unauth. event Unauth. alarm Max. door open Dependent door1 Dependent door2 Doors on fire Master users Users Alarms Fire alarm Medical alarm...
Page 21
SATEL INTEGRA Plus Lock Lock function Relay ON time Unauth. event Unauth. alarm Max. door open Dependent door1 Dependent door2 Doors on fire Master users Users Readers Reader A (does not apply to CA-64 DR) Reader A sound Reader A LED...
Page 22
Programming SATEL Filter [select zone to which wireless device is assigned] Remove device [select zone to which wireless device is assigned] Synchronization Test mode on Test mode off CA-64 E / CA-64 O / INT-ORS / INT-IORS / CA-64 SM No autorst.3t.
Microphone n [n = microphone number (1...4)] Speaker n [n = speaker number (1...4)] Only listen AVT buttons Sound signal. Silent alarm Satel commands Wait aft.event Wait aft.disc. Runtime No autorst.3t. Tamper in part. 2.1.6 Entering data by means of the keypad...
Page 24
Programming SATEL Programming telephone numbers Keep pressing particular keys until the required character appears. Characters available in the keypad are presented in Table 1. Up to 16 characters can be programmed. Some of the special characters (a, b, c, d, # and...
SATEL INTEGRA Plus Entering names Keep pressing particular keys until the required character appears. Characters available in the keypad are presented in Table 3. Hold down the key to display the digit assigned to the key. Shown on the left side in the upper line of the display is information about the letter case: [ABC] or [abc] (it will be displayed after pressing any key and will be visible for a few seconds after the last keystroke).
Page 26
Programming SATEL 3 - information on data writing/reading progress. 4 - icon indicating the status of communication with the control panel: – green color – ready to send data; – alternating green and yellow color – data transmission in progress;...
SATEL INTEGRA Plus - button saves the time in the control panel, based on the computer clock. - the button writes data into the control panel FLASH memory. - button displays a virtual keypad. - the button opens the drop-down menu, which makes available some tools to supervise the system state.
Programming SATEL To start the local programming function you can use the [service code] 01 key shortcut. 6. Establishing communication will be signaled on the monitor screen by a corresponding message. 2.2.4 Starting local programming "from pins" If the control panel does not support LCD keypads, does not accept the service code, etc., you can use the emergency procedure of, so-called, starting "from pins."...
Page 29
(built-in 300 bps modem or external analog modem). The control panel may only be remotely programmed from a specified locality. 3. Connection initialized by means of SMS (SATEL GSM module operating as an external modem). 4. Connection initialized by the control panel (all configurations). The control panel may only be remotely programmed from a specified locality.
Page 30
Programming SATEL 4. The D X program will inform you about establishing connection by means of LOAD a suitable message. Connection initialized from the program, but the control panel calls back LOAD and sets up the connection The telephone number of the alarm control panel must be programmed in the D LOAD program ("Identifiers and tel.
SATEL INTEGRA Plus the "Configuration" window, "Modem" tab). A suitable message will inform about the connection being established. Connection initiated by the control panel – external modem 1. Click on the button in the D X program. LOAD 2. A drop-down menu will be displayed. Select the "Modem - INTEGRA with ext. modem" in it.
Programming SATEL Configuring the D X program LOAD The following parameters required for establishing connection should be programmed in the "Identifiers and tel. no" window: the number of TCP port that will be used for communication (in most cases the port...
Page 33
SATEL INTEGRA Plus ISDN/GSM/ETHM MODEM A - ETHM/GSM. NSWERING You can program the above-mentioned options: using the keypad, in the service mode (O submenu); PTIONS using the D X program during local programming ("Options" window). LOAD...
Programming SATEL address is given in the SMS message (the computer address programmed in the GSM module will be ignored). 6. The D X program will inform you about establishing connection by means of LOAD a suitable message. 3. System structure The system can be subdivided into objects (subsystems).
SATEL INTEGRA Plus using the D X program, in the "Structure" window, "System" tab, after clicking on the LOAD object name – a new partition will be created after you click on the "Add" button. 3.2.2 Programming partitions You can program the partitions: ...
Page 36
Programming SATEL Partition type Armed with code [Normal] – the partition can be armed/disarmed by the user. With temporary blocking [With time bypass] – the partition can be armed/disarmed by the user, but on arming the partition is blocked for a time indicated by the user or determined by the installer (see D option).
Page 37
SATEL INTEGRA Plus Cash machine block delay [C.mach.blk.del.] – the time counted from the moment of entering the user code of the C type. After expiry of this time, ASH MACHINE ZONES BYPASSING the 24 type zones will be bypassed.
Programming SATEL Audible alarm after verification [Bell on 2nd] – if this option is enabled, the alarms from zones with the P or W option enabled will only trigger loud alarm ALARM ITH VERIFICATION signaling after verification. The unverified alarms will not trigger loud alarm signaling.
SATEL INTEGRA Plus INT-KSG with firmware version 1.02 (or later). The value of EOL resistors for the zones in zone expanders with firmware version 4.00 or later can be programmed: using the keypad, in the service mode, by means of EOL R1...
Page 40
Programming SATEL Alarm delay – refers to the 5. I and 6. E type zones. The alarm from zone may be NSTANT delayed by a programmed time period. Surveillance time – refers to the 8. E type zones. XTERIOR Bypass time – refers to the bypassing zones (zone types 64-79). It indicates for how long the zones will be bypassed.
Page 41
SATEL INTEGRA Plus Sensitivity – depending on wiring type: NO, NC, EOL, 2EOL/NC, 2EOL/NO, 3EOL/NC and 3EOL/NO – the time during which the zone must be violated, so that it can be noted by the control panel. Roller / Roller 2EOL – 2 parameters are to be programmed: Pulses duration –...
Programming SATEL disarmed. If the value 0 is programmed, control of this time is disabled. The time can be programmed in hours or minutes. It is recommended that you program the M parameter, since it will NO VIOLATION TIME provide an additional supervision of the detector connected to the zone.
Page 43
SATEL INTEGRA Plus C1...16 – the counting zones will signal an alarm when the number of 16...31 C OUNTING violations counted during a specified time period exceeds the set value (see: section p. 45). Violations of the counting zones in armed mode can be signaled at the OUNTERS 9.
Programming SATEL – intended for control of the external GSM 61. T – GSM ECHNICAL LINK TROUBLE communication module. Violation of the zone will cause a trouble condition. – intended for control of an additional power supply unit used 62. T –...
Page 45
SATEL INTEGRA Plus CHIME in module – with this option enabled, zone violation can be signaled in partition keypads, code locks and readers expanders assigned to the same partition as the zone (the option C must be enabled in the expander).
Page 46
Programming SATEL Abort delay – when this option is enabled, violating the zone during the entry delay countdown will result in registering a "Zone violation" event (this event can only be reported in the 4/2 format). When the option is disabled, violating the zone during the entry delay countdown will result in registering an "Alarm"...
SATEL INTEGRA Plus Blocks verification – option for 0-2 and 85-86 zone types. If it is enabled, violation of the zone will block verification of alarms in the partition. All alarms will be unverified until the partition is armed again.
Programming SATEL 3.3.9 Groups of partitions You can define up to 16 partition groups which will be controlled using the 80. A RMING 81. D and 83. C type zones. The partition groups can be defined: ISARMING LEARING ALARM using the keypad, in the service mode, by means of the G function (Z...
SATEL INTEGRA Plus Fig. 6. "Outputs" window in the D X program. LOAD Output parameters Output name – individual name of the output (up to 16 characters). Output function (see: section O UTPUT FUNCTIONS Cut off time – time during which the output is active. The parameter is irrelevant for the status indicating outputs.
Page 50
Programming SATEL ) – signals the fire alarms triggered from keypad. 5. F FROM KEYPAD ) – signals the loud panic alarms triggered from keypad. 6. P ANIC FROM KEYPAD ) – signals the medical assistance call alarm triggered from 7.
Page 51
SATEL INTEGRA Plus The pulse duration is approx. 0.3 seconds. – controlled by users, zones or timers. Using a code, zone violation or 24. MONO S WITCH turning timer on will activate the output for a preprogrammed time. – controlled by users, zones or timers. Depending on the current status, using 25.
Page 52
Programming SATEL option, the output can be used for logical negation). See: L OLARITY OGICAL FUNCTIONS OF . s. 55. OUTPUTS OR – active when any control output with normal polarity is active or 47. O UTPUTS LOGICAL any control output with reversed polarity is inactive (because of the P...
Page 53
SATEL INTEGRA Plus – similarly as types 64-79, but the numbers of remote switches must be 98. R EMOTE SWITCH selected. – signals read-in of the user card. 99. A CCESS CARD READ – signals holding the user card. 100. C –...
Programming SATEL – active when selected partitions are armed in the selected mode. 115. A RMING TYPE STATUS – signals the same alarms and violations as the 1. B or 9. DAY 116. I URGLARY NTERNAL SIREN output type (logic product of the 1. B and 9.
SATEL INTEGRA Plus LCD keypads – indicate the LCD keypads. The output will be controlled by events related to these LCD keypads. Partitions – indicate the partitions/partition keypads. The output will be controlled by events related to these partitions/partition keypads.
Programming SATEL The user can edit the temperature thresholds using the T user function EMPERATURES available in the C submenu. HANGE OPTIONS Output forcing T1 – you can indicate the output which will force the first temperature threshold. If the output is active, the first temperature threshold will be active. When the output is inactive, the control timers will decide which temperature threshold is active.
SATEL INTEGRA Plus The output can be assigned to a few groups. If the output is not assigned to any group, it cannot be controlled from the keypad. Output state indicating In case of the 24. MONO , 25. BI and 64...79 R...
SMS messaging – if this option is enabled, the control panel can send notifications of the occurrence of specific events using SMS messages, the content of which is consistent with event description in the event log (the SATEL GSM module must be connected to the control panel).
SATEL INTEGRA Plus Ground Start – with this option enabled, the control panel will use the Ground Start method to obtain signal on the telephone line (by grounding temporarily the telephone line wires). Enable this option, if required by your phone service provider.
Programming SATEL 5.2.2 Printout contents The options define what kind of information will be contained in the printout. Other options Permitted "simple" access codes [Simple codes] – with this option enabled, with this option enabled, it is possible to use codes containing less than three different digits (e.g.
Page 61
SATEL INTEGRA Plus Grade 3 – with this option enabled, the system operates as required by the EN 50131 standard for Grade 3, i.e.: – starting the arming procedure may be impossible, or, if started, the arming procedure may fail, if some zones are violated in the partition, or there is a trouble in the system;...
Programming SATEL – the quick arming is not possible (relevant parameters in keypads settings are automatically modified); – the S option is enabled in all keypads (it cannot be disabled); HOW ARM MESSAGES – the following options are disabled in all keypads (they cannot be enabled):...
SATEL INTEGRA Plus Do not arm if reporting trouble [If monit.trbl.] – if this option is enabled, arming will be impossible in case of any problems with reporting. The options D O NOT ARM IF TAMPERED O NOT ARM IF BATTERY TROUBLE...
Page 64
Programming SATEL – DURESS – to be used, when the user is forced to enter the code. If used, a silent alarm will be triggered. By default, it consists of a suitable number of digits 4 (e.g. if the prefix length has been set at 3, the default prefix will be: 444).
SATEL INTEGRA Plus Default user's authority level You can define which user rights will be automatically assigned to a new user. The list of permissions can be modified during user creating or editing. 6. Programming the keypads You can program the keypads: ...
Page 66
Programming SATEL Keys backlight – selection of the keypad backlighting type. Fig. 8. Example of LCD keypad settings. Alarm messages – you can define whether the keypad is to display text messages about alarms: – in partitions [Part.al.msg.]; – from zones [Zone al.msg.].
Page 67
SATEL INTEGRA Plus – the authorization method depends on the status of selected output (the output active – code and card; the output inactive – code or card). In case of the authorization using code and card, the executed function depends on the second identifier.
Page 68
Programming SATEL Show disarm messages [Show disarming] – if this option is enabled, the keypad will inform about disarming with a displayed message at all times. If the option is disabled – only in case of disarming from the given keypad.
SATEL INTEGRA Plus Permanently displayed partitions [State part.] – you can select the partitions whose state will be permanently presented in the lower line of the display. Up to 16 partitions can be selected. The partitions are displayed successively: for example, if the partitions 3, 6 and 7 are selected, their state will be displayed in the first, second and third position of the display.
via telephone line; over the Ethernet network – if ETHM-1 module is connected, using GPRS technology – if the SATEL GSM module is connected. The control panel will make an attempt to send an event code according to the following order: 1.
Page 71
SATEL INTEGRA Plus panel will make repeated monitoring attempts. If the event cannot be sent despite completion of the preprogrammed number of retries, the control panel will hang up until a next event occurs, or for a specified period of time. After the time expires, the control panel will make further attempts to send the event.
Programming SATEL Before you proceed to the programming, obtain from the monitoring station operator all data necessary to correctly start the reporting function: depending on the method of sending events: – telephone number of the monitoring station (telephone reporting);...
Port – the number of port through which communication with the monitoring station will be effected. IP format – events can be sent using the SATEL or SIA-IP format (SIA DC-09 standard). The SIA-IP format can be used, if an ETHM-1 module with firmware version 1.06 or newer is connected to the control panel.
Programming SATEL Identifiers Each event code is sent to the monitoring station with an identifier. Up to 8 identifiers plus a system identifier can be programmed. Sent with the system identifier are events related to the alarm system (troubles, tests, etc.).
SATEL INTEGRA Plus In case of the C ID ( ) and SIA ( ) formats, indicate the events ONTACT SELECTED SELECTED which are to be reported, entering for them any code different from "00" (a code consistent with the format specification will be sent, not the entered one). The events for which the "00"...
– reporting format in which the codes will be sent, – server address, – port number, – IP format in which the codes will be sent (SATEL or SIA-IP), – encryption key (S ) and control panel identifier for the purposes of reporting...
The control panel can inform you about the system events by means of: voice messages (the INT-VG module or another voice synthesizer must be connected); PAGER type text messages defined by the installer (the SATEL GSM modules enable the PAGER messages to be converted into SMS);...
Programming SATEL Number of rounds – the number of attempts made by the control panel to notify the selected telephone number about the event, if the message reception has not been acknowledged. If the value 0 is entered, messaging for the indicated telephone number will be disabled.
For messaging using the PAGER type messages, you must define the parameters of pager identification. Default parameters of the pager type 1 are adjusted to the SATEL GSM module requirements for conversion of the PAGER type message into SMS message.
Programming SATEL 11. Answering phone calls and remote control The call answering function allows the control panel users to receive information on the partition status (arm mode, alarms). Owing to the telephone control function, the users can control the R outputs by means of a telephone.
EMOTE SWITCH 12. Control panel firmware replacement Available on the www.satel.eu website is the current version of control panel firmware and the F X program enabling to write it to the control panel. In order to replace the firmware: LASH 1.
Programming SATEL 13. Manual update history Firmware Date Introduced changes version 2013-08 1.12 Information on INTEGRA 256 Plus control panel has been added. Section "Hiding the service mode" has been added (p. 5). List of functions available in the service mode menu has been supplemented (p.