Power supply
Ê Install the power supply units as described in section
power supply unit" on page
6.3.4.4

Concluding steps

"Reassembling" on page 52
Ê
"Connecting the server to the mains" on page 55
Ê
"Switching on the server" on page 57
Ê
"Enabling BitLocker functionality" on page 84
Ê
6.4
Converting a standard power supply to a
redundant power supply
The standard power supply can be replaced by a redundant power supply. The
redundant power supply consists of up to two power supply units (slide-in units).
The upgrade kit contains only one power supply unit (for power supply
redundancy the second power supply unit must be additionally ordered).
The upgrade kit for the redundant power supply consists of the following parts:
– PSU cage with power distribution board
– two power cables
– one hot-plug power supply unit
– dummy cover (if only one power supply unit is installed, you have to install
the dummy cover in the second bay)
– several screws
– one fan module
Field Replaceable Unit
(FRU)
Tools: Phillips PH2 / (+) No. 2 screw driver