Honeywell DCP552 Mark II User Manual page 61

Digital control programmer
Table of Contents

Advertisement

Mode event
This event goes on or off depending on controller mode, alarm generation and
other states.
It cannot be combined with the event standby function but with the on delay
function. It does not set event set values (operating points) or hysteresis.
• Basic operations
• Alarm
• ADV
The following types are provided.
RUN + HOLD + END + FAST
HOLD
READY + READY FAST
END
G.SOAK wait
MANUAL
During auto-turning execution
FAST + READY FAST
Console setting operation
RUN
ADV (advance)
Full alarm (logical OR)
PV range alarm
Instrument alarm
O
sensor failure
2
Battery voltage drop
The event goes on when the specified instrument state is reached and is off at
other times.
Alarms are of two types: PV range alarm group (alarm code number 01 to 04)
and instrument alarm group (alarm code number 91 to 99 and battery voltage
drop). When the event type is all alarm, the event goes on if one alarm occurs.
When the event type is a PV range alarm, the event goes on if one alarm in the
PV range alarm group goes on.
When the event type is an instrument alarm, the event goes on if one alarm in
the instrument alarm group goes on.
When ADV (advance) is executed, the event goes on for 1 second. This
function is valid during on delay.
Chapter 5. FUNCTIONS
5-15

Advertisement

Table of Contents
loading

Table of Contents