No. Item code
Item
79 PA 79
PV2 equalizer compensation point No. 5 2000 PVU
80 PA 80
PV2 equalizer compensation amount No. 5 0 PVU
81 PA 81
PV2 equalizer compensation point No. 6 2500 PVU
82 PA 82
PV2 equalizer compensation amount No. 6 0 PVU
83 PA 83
PV2 equalizer compensation point No. 7 3000 PVU
84 PA 84
PV2 equalizer compensation amount No. 7 0 PVU
85 PA 85
PV2 equalizer compensation point No. 8 3500 PVU
86 PA 86
PV2 equalizer compensation amount No. 8 0 PVU
87 PA 87
PV2 equalizer compensation point No. 9 4000 PVU
88 PA 88
PV2 equalizer compensation amount No. 9 0 PVU
89 PA 89
PV2 equalizer compensation point No. 10 Range upper
90 PA 90
PV2 equalizer compensation amount No. 10 0 PVU
93 PA 93
Auto-tuning (CH2)
94 PA 94
Auto-tuning MV lower limit (CH2) 0.0
95 PA 95
Auto-tuning MV upper limit (CH2) 100.0
96 PA 96
PID computation initialize (CH2) 0
97 PA 97
CPU computation compensation 0
98 PA 98
CP value (PV) display lower limit value 0.000
99 PA 99
CP value (PV) display upper limit value 4.000
100 PA100
Gas constant
101 PA101
CP computation compensation 0.000
No.1 compensation point
102 PA102
CP computation compensation 0.000
No.1 compensation amount
103 PA103
CP computation compensation 0.200
No.2 compensation point
104 PA104
CP computation compensation 0.000
No.2 compensation amount
105 PA105
CP computation compensation 0.400
No.3 compensation point
106 PA106
CP computation compensation 0.000
No.3 compensation amount
107 PA107
CP computation compensation 0.600
No.4 compensation point
108 PA108
CP computation compensation 0.000
No.4 compensation amount
109 PA109
CP computation compensation 0.800
No.5 compensation point
110 PA110
CP computation compensation 0.000
No.5 compensation amount
denotes items settable only on models with CP compensation
Factory default User
settings
settings
–19999 to +20000 PVU(PV2)
–1000 to +1000 PVU(PV2)
–19999 to +20000 PVU(PV2)
–1000 to +1000 PVU(PV2)
–19999 to +20000 PVU(PV2)
–1000 to +1000 PVU(PV2)
–19999 to +20000 PVU(PV2)
–1000 to +1000 PVU(PV2)
–19999 to +20000 PVU(PV2)
–1000 to +1000 PVU ( PV2 )
PV2 range upper limit value (tied)
limit value
–1000 to +1000 PVU(PV2)
0
0 : AT not performed
1 : standard AT performed on currently used PID group in
mode other than READY mode.
2 : AT writing overshoot-proof PID values to currently used
PID groups in mode other than READY mode performed.
3 : Standard AT performed on PID groups A1 to A7 in
READY mode.
4 : AT writing overshoot-proof PID values to PID groups A1
to A7 in READY mode continuously performed.
-5.0 to upper limit %
Lower limit to +105%
0 : No initialization during advance processing and PID
group change
1 : Initializes during advance processing but not during PID
group change
2 : No initialization during advance processing but
initializes during PID group change
3 : Initializes both during advance processing and PID
group change
0 : no compensation
1 : compensates
0 to upper limit SPU (CH2)
lower limit to 4000 SPU (CH2)
23.5
10.0 to 50.0
0 SPU (CH2) (tied)
-1000 to +1000 SPU (CH2)
0 to 2000 SPU (CH2)
-1000 to +1000 SPU (CH2)
0 to 2000 SPU (CH2)
-1000 to +1000 SPU (CH2)
0 to 2000 SPU (CH2)
-1000 to +1000 SPU (CH2)
0 to 2000 SPU (CH2)
-1000 to +1000 SPU (CH2)
DCP552 Parameter Work Sheet