Enter/Exit Programming Mode
Advanced formatting is available to create user label edit scripts. See the Datalogic Aladdin
configuration application or contact Technical Support.
This feature allows conversion of the case of all alphabetic characters to upper or lower case.
DEFAULT
$CLFCA01(CR)
Case Conversion = Convert to upper case
Character conversion is an eight byte configuration item. The eight bytes are 4 character
pairs represented in hexadecimal ASCII values. The first character in the pair is the character
that will be converted. The second character in the pair is the character to convert to. If the
character to convert in a pair is FF, then no conversion is done.
58

Advanced Formatting: User Label Edit

Case Conversion

Case conversion affects ONLY scanned bar code data, and does not affect Label
ID, Prefix, Suffix, or other appended data.

Character Conversion

If less than the expected string of 16 characters are selected, scan the ENTER/
EXIT bar code twice to accept the selections and exit Programming Mode.
DEFAULT
(No character conversion)
$CLFCA00(CR)
Case Conversion = Disable (no case conversion)
$CLFCA02(CR)
Case Conversion = Convert to lower case
$CLFCH
Configure Character Conversion
0xFFFFFFFFFFFFFFFF