Xantrex XW4024-120 Operation Manual page 80

Xw series hybrid inverter/charger
Table of Contents

Advertisement

Troubleshooting
Table 4-2 Warning Messages
Warning
System Control
Number
Panel Message
W96
Cannot Equalize
W97
Battery temp sensor
failure.
W500
Lost network
connection
W501
Inv/Chg is trying to
fix a memory
problem
4–14
Warning
Type
Cause
Manual
The selected battery type
should not be equalized.
Automatic
Battery Temperature Sensor
Shorted
Automatic
Lost network connection
Manual
Non-volatile memory
warning
Solution
Change battery type if your
batteries should be equalized. Gel
or AGM batteries should not be
equalized.
Replace battery temperature
sensor.
Check network cables.
Normal operation may return or
may go to fault. Turn inverter/
charger off and on to resume
normal operation.
975-0240-01-01

Advertisement

Table of Contents
loading

Table of Contents