975-0240-01-01
To select the Advanced or Basic settings:
u From the Setup menu, with Basic Settings or Advanced Settings highlighted,
press Enter. See Figure 3-2.
XW6048 00: Setup
Advanced Settings
[Enabled]
[Disabled]
[Disabled]
[Enabled]
[Disabled]
[Operating]
Figure 3-2 Selecting Advanced Settings
To select and change a configurable setting:
1. On the desired configuration menu, press the up arrow or down arrow button
to highlight the setting you want to change.
2. Press Enter to highlight the current value of the setting.
3. Press the up arrow or the down arrow button to change the value. Hold down
the button to scroll through a large range of values quickly.
The previously set value appears with an asterisk (*) beside it.
4. Press Enter to select the value.
5. If you have another setting to change, return to step 1.
Or
If you have no more settings to change, press Exit until the System Control
Panel displays the desired screen or menu.
Important:
If you have no more settings to change, it is recommended to leave the
Setup menu in the Basic Settings format to help prevent unintended configuration. If the
Setup menu displays "Advanced Settings," press Enter + up arrow + down arrow at the
same time. The Setup menu should then display "Basic Settings" as the last item on the
menu.
XW6048 00: Adv