Digital I/O - REXROTH VT-VRPD-2 Start-Up And Operation

Digital valve amplifier for valve types 4wre 6, 10 component series 2x
Table of Contents

Advertisement

RE 30126-01-B/08.07 | Manual

Digital I/O

Outputs
Clicking on the preceding icon, which is a component of the toolbar,
also opens the "Command values" window. A list of existing shortcuts
for the toolbar can be found in Section 4.2 "BODAC Toolbar".
See also: Section 3.4 "Configure profiles".
Opens the window „Digital I/O".
Clicking on the preceding symbol, which is a component of the
toolbar, also opens the „Digital I/O" window. A list of existing
shortcuts for the toolbar can be found in Section 4.2 „BODAC
Toolbar".
Fig. 44 Window „Digital I/O"
Defines under what conditions the Digital Outputs are set. DO1 – DO3 conditions are
pre-defined and can not be changed. DO4 – DO6 can be configured as follows:
n
OFF
The Digital Output is not active.
n
LVDT>=WINDOW
The actual value exceeds or is equal to a set value (WINDOW).
n
LVDT<=WINDOW
The actual value is less than or equal to a set value (WINDOW).
n
Ramp done
The Ramp is done.
n
Fault Analog Inputs
A fault concerning the analog inputs has been detected. If the user wants to use
this condition to set an output the respons e of this fault has to be set to "Flag" in
the "Fault" window. For detailed information on configuring the "Fault" window
please see also Section 3.5 „Configure Profile"
Hydraulics | Bosch Rexroth AG
BODAC – Menu Description 5
63/76

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents