Start Application - REXROTH VT-VRPD-2 Start-Up And Operation

Digital valve amplifier for valve types 4wre 6, 10 component series 2x
Table of Contents

Advertisement

RE 30126-01-B/08.07 | Manual
Test jacks -
File menu
Test jacks -
Controller menu
Test jacks -
Help menu
Test jacks
3.9

Start Application

Start-up
Clicking on the preceding icon, which is a component of the toolbar,
also opens the "Test points" window. A list of existing shortcuts for the
toolbar can be found in Section 4.2 "BODAC Toolbar".
Fig. 17 "Test jacks" window
The File menu in the "Test jacks" window corresponds to the BODAC main window
"File menu".
The Controller menu contains commands for reading, writing and modifying
param eters.
The Help menu takes you directly to the help for the current topic, or to the contents
page of the BODAC windows help.
Test jack X1 is permanently set to the actual value „LVDT". X2 can be configured as
the command before the Command Adjustment (LC1) or the Command after the
Command Adjustment (OUT1).
The application is started by setting the digital input „Enable" (d18).
See also "Electric and Hydraulic Installation plan"
Hydraulics | Bosch Rexroth AG
Application: Valve control for the 4WRE6 / 4WRE10 3
33/76