REXROTH VT-VRPD-2 Start-Up And Operation page 50

Digital valve amplifier for valve types 4wre 6, 10 component series 2x
Table of Contents

Advertisement

RE 30126-01-B/08.07 | Manual
Min fault
Max fault
Max unit
100
-10
-100
Assignments are made with the mouse button. Clicking on the "Type" entry field
opens a selection field containing the following:
n
+/-10 V
Type
The expected input signal varies in a range of (–10 V) to (+10 V).
n
0~10 V
An input signal of from (0 V) to (+10 V) is expected.
n
4~20 mA
The current level of the input signal varies between (4 mA) and (20 mA).
Range
The "Range" column is where you enter the signal value range in [%]. A signal of (-
10V) for a range setting of ±100% corresponds to a signal of (-100%).
The relationship is shown in the graphic below
Min
The "Min" setting is used to limit the minimum input signal to a value you determine
within the type range (±10 V). For example, a value of (-5 V) means the signal (-5 V) is
interpreted as (-100%) range (see Fig. 41 Analog I/O - Input adjustments).
Max
The "Max" setting is the opposite of "Min". For example, a value of (+9 V) means the
signal (+9 V) is interpreted as (+100%) range (see Fig. 41 Analog I/O - Input
adjus tments).
The setting for the value "Min Error" is used to specify the minimum error. When the
signal falls below this entered value, BODAC uses the "Status" window to indicate that
a fault has occurred if the fault is activated in the "Faults" window.
The setting for the value „Max Error" is used to specify the maximum error. When the
signal exceeds this entered value, BODAC uses the "Status" window to indicate that a
fault has occurred if the fault is activated in the "Faults" window.
The "Max Units" setting specifies the value range of the signal in units [Unit].
The following example shows in table and graphic form the parameters for a signal
adjustment in the Inputs field.
10
-100
Fig. 28 Analog I/O input adjustments
Hydraulics | Bosch Rexroth AG
Max [V]
9
100
-5
Min [V]
BODAC – Menu Description 5
Max Unit
100
[Units]
-5
-Min [V]
-100
Max Unit
[Units ]
50/76
9
Max [V]
analoge_ea_diag