Data Exchange Between The Bodac Software And The Vt-Vrpd Controller Card; Open Or Create Parameter File - REXROTH VT-VRPD-2 Start-Up And Operation

Digital valve amplifier for valve types 4wre 6, 10 component series 2x
Table of Contents

Advertisement

RE 30126-01-B/08.07 | Manual
3.2
Data exchange between the BODAC software and the VT-VRPD
controller card
3.3

Open or create parameter file

Open parameter file
Create parameter file
Establish an RS-232 connection between the PC and the VT-VRPD so that you can
configure, save and duplicate the desired data for your controller card.
The baud rate (57600 baud) is fixed in the card.
Ø
Connect PC to VT-VRPD using an RS-232 cable (1:1 cable)
e.g. cable set: VT-HACD-1x/03.0/HACD-PC, Material-No. R900776897,
length 3 m
Ø
Turn on PC and VT-VRPD
Ø
Install BODAC.
Ø
Start BODAC (see section 4 "BODAC user interface").
USB converter:
If the PC has no serial port, an USB/RS232 interface converter may be
used. (Can be ordered using material number R901066684.)
The card is configured depending on the application. The data for configuration and
parameterisation are saved in a file (FILENAME.PARAM) and stored in the predefined
directory \user\.
Assign a file name and save the beginning state.
If there are no param eter files, you are prompted after program start to
open a default file.
See section "Open".
See section "Save".
Hydraulics | Bosch Rexroth AG
Application: Valve control for the 4WRE6 / 4WRE10 3
17/76