Connecting the valve position transducer

Connection for the valve position transducer is shown in the following illustration.
Valve position feedback connection
Fig. 3 Connecting the valve transducer
The transducer is connected using a 4-pole cable connector Pg7-G5W1F, which can
be ordered separately under material number R900023126.
Cable 4 x 0.25 mm² of type LiYCY-CY ( 4 x 30 AWG Double shielded cable) is
recommended for lengths up to 50 m.
The shield should be connected to z10 on the edge connector of the controller on the
supply side only.
Hydraulics | Bosch Rexroth AG