RE 30126-01-B/08.07 | Manual

Options

General
The "Options" window defines the frequency and type of data transmission to the
controller card.
Fig. 34 "Options, general" window
In this window, you can select, which monitoring routines are to be executed
automatically by BODAC after a change of data.
WRITE TO CONTROLLER PROMPT: If settings or parameters were changed in
BODAC without having been saved in the controller card, BODAC can show a
corresponding warning window:
- On closing the window, in which changes were made
- On BODAC closing
SET TO MEMORY PROMPT: When changed values are written to the controller, they
are only saved in the volatile memory of the controller card. For permanent saving, the
data must be set to the memory. Here, you can set, when BODAC saves the values
automatically in the permanent memory of the controller card:
- Every write to controller.
- On form closing.
- On BODAC closing.
With the selection "Automatically write changes to the controller before setting to
memory", you make sure that the parameters changed by you in BODAC are
transmitted before they are saved in the permanent mem ory of the controller.
If you deactivate these monitoring functions, you can nevertheless
ensure that changed parameters are written to the controller card and
saved in the permanent memory at least at the end of commissioning.