Status; Test Jacks - REXROTH VT-VRPD-2 Start-Up And Operation

Digital valve amplifier for valve types 4wre 6, 10 component series 2x
Table of Contents

Advertisement

RE 30126-01-B/08.07 | Manual

Status

Test jacks

The „Status" window provides an overview of the current faults that were detected
while the controller card was running.
Clicking on the preceding icon, which i spart of the toolbar, also opens
Status
the „Status" window. A listing of existing shortcuts for the toolbar can
be found in Section 4.2 "BODAC Toolbar".
Fig. 16 Window „Status"
The signals monitored can have the following status:
n
OK
No faults .
n
ERROR
A Fault was detected. This Fault was configured as a „ERROR" in the „Fault"
window resulting in the detection of the Fault but not switching off the controller.
Not every Fault can be configured as a "ERROR". See also Section "Faults".
n
STOP
A Fault was detected. This Fault was configured as a „STOP" in the „Fault"
window resulting in switching off the controller. See also Section "Faults".
In this window you can configure the test jacks: You specify which control parameter
is available on the test points.