"C" Group: Intelligent Terminal Functions

The eight input terminals [1], [2], [3], [4], [5], [6], [7], and [8] can be configured for any of 44
different functions. The next two tables show how to configure the eight terminals. The inputs
are logical, in that they are either OFF or ON. We define these states as OFF=0, and ON=1.
The inverter comes with default options for the eight terminals. These default settings are
initially unique, each one having its own setting. Note that European and US versions have
different default settings. You can use any option on any terminal, and even use the same option
twice to create a logical OR (though usually not required).
Input Terminal
Functions and Options –The function codes in the following table let you assign one of 44
options to any of the eight logic inputs for the SJ300 inverters. The functions C001 through
Configuration
C008 configure the terminals [1] through [8] respectively. The "value" of these particular
parameters is not a scalar value, but it is a discrete number that selects one option from many
available options.
For example, if you set function C001=01, you have assigned option 01 (Reverse Run) to
terminal [1]. The option codes and the specifics of how each one works are in Chapter 4.
"C" Function
Func.
Name
Code
C001 Terminal [1] function
C002 Terminal [2] function
C003 Terminal [3] function
C004 Terminal [4] function
C005 Terminal [5] function
C006 Terminal [6] function
C007 Terminal [7] function
C008 Terminal [8] function
Run
Mode
Edit
Description
Lo Hi
✘ ✔
✘ ✔
✘ ✔
✘ ✔
44 programmable
functions available
for terminals (see
✘ ✔
next section)
✘ ✔
✘ ✔
✘ ✔
Defaults
Units
–FE
–FU
–FR
(EU)
(US)
(JP)
18
18
18
[RS]
[RS]
[RS]
16
16
16
[AT]
[AT]
[AT]
06
06
06
[JG]
[JG]
[JG]
11
11
11
[FRS]
[FRS]
[FRS]
09
09
09
[2CH]
[2CH]
[2CH]
03
13
03
[CF2]
[USP]
[CF2]
02
02
02
[CF1]
[CF1]
[CF1]
01
01
01
[RV]
[RV]
[RV]
3–47
SJ300 Inverter
SRW Display
>C001 IN-TM
1
RS
>C002 IN-TM
2
AT
>C003 IN-TM
3
JG
>C004 IN-TM
4
FRS
>C005 IN-TM
5
2CH
>C006 IN-TM
6
USP
>C007 IN-TM
7
CF1
>C008 IN-TM
8
RV

Advertisement