"F" Group: Main Profile Parameters

"F" Group: Main Profile Parameters
Func.
Name
Code
F001
Output frequency
setting
F002
Acceleration (1) time
setting
F202
Acceleration (1) time
setting, 2nd motor
F302
Acceleration (1) time
setting, 3rd motor
F003
Deceleration (1) time
setting
F203
Deceleration (1) time
setting, 2nd motor
F303
Deceleration (1) time
setting, 3rd motor
F004
Keypad Run key routing Two options; select codes:
The basic frequency (speed) profile is
defined by parameters contained in the
"F" Group as shown to the right. The
output frequency is set in Hz, but accel-
eration and deceleration are specified
seconds (the time to ramp from zero to
maximum frequency, or from maximum
frequency to zero). The motor direction
parameter determines whether the
keypad Run key produces a FW or RV
command. This parameter does not
affect the [FW] terminal or [RV] intelligent terminal function, which you configure separately.
Acceleration 1 and Deceleration 1 are the standard default accel and decel values for the main
profile. Accel and decel values for an alternative profile are specified by using parameters Ax92
through Ax93. The motor direction selection (F004) determines the direction of rotation as
commanded only from the keypad. This setting applies to any motor profile (1st, 2nd, or 3rd) in
use at a particular time.
"F" Function
Description
Standard default target
frequency that determines
constant motor speed
Range is 0 to 400 Hz
Standard default accelera-
tion
Range is 0.01 to 3600 sec.
Standard default accelera-
tion, 2nd motor
Range is 0.01 to 3600 sec.
Standard default accelera-
tion, 3rd motor
Range is 0.01 to 3600 sec.
Standard default decelera-
tion
Range is 0.01 to 3600 sec.
Standard default decelera-
tion, 2nd motor
Range is 0.01 to 3600 sec.
Standard default decelera-
tion, 3rd motor
Range is 0.01 to 3600 sec.
00 Forward
01 Reverse
Output
F002
frequency
F001
Defaults
Run
Mode
Edit
–FE
–FU
–FR
Lo Hi
(EU)
(US)
(JP)
✔ ✔
0.00
0.00
0.00
✔ ✔
30.0
30.0
30.0
✔ ✔
30.0
30.0
30.0
✔ ✔
30.0
30.0
30.0
✔ ✔
30.0
30.0
30.0
✔ ✔
30.0
30.0
30.0
✔ ✔
30.0
30.0
30.0
✘ ✘
00
00
00
F003
t
Units
SRW Display
Hz
>F001 SET-Freq.
TM
0000.00Hz
2FS
0000.00Hz
3FS
0000.00Hz
TM
0000.00Hz
JG
0000.00Hz
1S
0000.00Hz
15S
0000.00Hz
OP1
0000.00Hz
OP2
0000.00Hz
RS485
0000.00Hz
sec.
>F002 ACCEL
TIME1
0030.00s
sec.
>F202 2ACCEL
TIME1
0030.00s
sec.
>F302 3ACCEL
TIME1
0030.00s
sec.
>F003 DECEL
TIME1
0030.00s
sec.
>F203 2DECEL
TIME1
0030.00s
sec.
>F303 3DECEL
TIME1
0030.00s
>F004 DIG-RUN
SELECT
FW