2–16
Step-by-Step Basic Installation
Terminal
Dimensions and
Torque Specs
Input
Voltage
200V
The following tables list the screw size of terminal and recommended torque for tightening for
each of the SJ300 inverter models (400V models are on the next page).
CAUTION: Fasten the screws with the specified fastening torque in the table below. Check for
any loosening of screws. Otherwise, there is the danger of fire.
Motor
200V
Output
Inverter Models
HP
kW
1/2
0.4
SJ300-004LFU
1
0.75
SJ300-007LFU
2
1.5
SJ300-015LFU
3
2.2
SJ300-022LFU
5
3.7
SJ300-037LFU
7.5
5.5
SJ300-055LFU
10
7.5
SJ300-075LFU
15
11
SJ300-110LFU
20
15
SJ300-150LFU
25
18.5
SJ300-185LFU
30
22
SJ300-220LFU
40
30
SJ300-300LFU
50
37
SJ300-370LFU
60
45
SJ300-450LFU
75
55
SJ300-550LFU
Note 1: The recommended ring lug connector listing consists of wire size – screw size
format. The wire sizes are in AWG or mm
for the ring lug centers are: #10, #12, 1/4", 5/16", and 1/2". For metric wire sizes,
bolt sizes for the ring lug centers are: 6 = 6M, 8 = 8M, 10 = 10M.
TIP: AWG = American Wire Gauge. Smaller numbers represent increasing wire thickness.
kcmil = 1,000 circular mils, a measure of wire cross-sectional area
2
mm
= square millimeters, a measure of wire cross-sectional area
Ring lug connector *1
Screw size
of terminal
(AWG-bolt)
M4
20–#10
M4
20–#10
M4
14–#10
M4
14–#10
M4
10–#10
M5
8–#12
M5
8–#12
M6
4–1/4
M6
2–1/4
M6
1–1/4
M8
1/0–5/16
M8
2–5/16
M8
1–5/16
M10
1/0–1/2
M10
2/0–1/2
2
format. For AWG wire sizes, bolt sizes
Torque
2
ft-lbs
(N-m)
(mm
–bolt)
1.25–4
1.1
1.5
1.25–4
1.1
1.5
2–4
1.1
1.5
2–4
1.1
1.5
3.5–4
1.1
1.5
5.5–5
1.8
2.5
8–5
1.8
2.5
14–6
3.6
4.9
22–6
3.6
4.9
30–6
3.6
4.9
38–8
6.5
8.8
60–8
6.5
8.8
100–8
6.5
8.8
100–10
10.1
13.7
150–10
10.1
13.7

Advertisement