Capacitor Replacement - Hitachi SJ300 Series Instruction Manual

Hitachi instruction manual inverter sj300 series
Hide thumbs Also See for SJ300 Series:
Table of Contents

Advertisement

Capacitor
The capacitor bank consists of an assembly that slides out of the SJ300 unit. This means that no
soldering is required!
Replacement
1. First, make sure that all power is removed
WARNING: The screws that retain the capacitor bank assembly are part of the electrical
circuit of the high-voltage internal DC bus. Be sure that all power has been disconnected from
the inverter, and that you have waited at least 5 minutes before accessing the terminals or
screws. Be sure the charge lamp is extinguished. Otherwise, there is the danger of electrocution
to personnel.
2. The capacitor bank assembly is locked into
3. Grasp the capacitor bank assembly and gently
4. Then slide in the new unit and replace all the
CAUTION: Do not operate the inverter unless
you have replaced the two screws that connect
the capacitor bank assembly to the internal DC
bus. Otherwise, damage to the inverter may
occur.
from the unit, and that you have waited 5
minutes before accessing the wiring area. Then
you'll need to remove the metal wire entry
plate located at the bottom of the unit. This
may require you to disconnect all wires to the
power terminals. Then, just loosen the screws
as shown, and slide the wire entry plate
outward on its guides to remove.
the inverter via two screws that also make the
electrical connection to the internal DC bus.
These two screws are accessible just below
the power terminals as shown to the right.
slide it out of the unit as shown to the right. DO
NOT try to force the removal; it will slide out
easily if all the screws in the steps above have
been removed.
screws removed in steps 1) and 2).
SJ300 Inverter
Retention screws for wire entry plate
Retention screws for capacitor bank
Pull capacitor bank assembly outward
from SJ300 unit to remove
6–13

Advertisement

Table of Contents
loading

Table of Contents