LOW BATTERY CONDITION
During unit operation, voltage level is checked every 10 minutes. A Low Bat-
tery condition is indicated by the Battery icon appearing on the display (Fig.
69a). Upon decreasing to a voltage level that will not maintain proper unit op-
eration, the icon will flash for 5 seconds followed by shutdown of the unit.
If the unit did not display the Low Battery icon 'prior' to entering the Dive
mode, and a low battery condition occurs during a dive, you will be alerted by
the Low Battery icon appearing on the display. There will be sufficient battery
power to maintain unit operation 'for the remainder of that dive', however the
backlight will be disabled.
BATTERY REPLACEMENT
NOTE: The following procedure must be closely adhered to.
Damage due to improper battery replacement is not covered by
the Data Plus 2 limited 2 year warranty.
MODULE REMOVAL FROM BOOT
Wrist or Hose Mount Boot - peel the lips of the boot downward off the module
while applying pressure from underneath, working it out slowly.