Specifications - Oceanic DATA PLUS Owner's Manual

Oceanic data plus 2
Hide thumbs Also See for DATA PLUS:
Table of Contents

Advertisement

®
NO DECOMPRESSION MODEL
Basis:
• Modified Haldanean Algorithm
• 12 tissue compartments
Data Base:
• Diving Science and Technology (DSAT) - Rogers/Powell
Performance:
• Tissue compartment halftimes (in mins.) Spencer's "M" values
5, 10, 20, 40, 80, 120, 160, 200, 240, 320, 400, 480
• Reciprocal subsurface elimination
• 60 minute surface credit control for compartments faster than 60 minutes
• Tissue compartments tracked up to 24 hours after last dive
Decompression Capabilities:
• Decompression stop ceilings at 10, 20, 30, 40, 50, & 60 feet
(3, 6, 9, 12, 15, & 18 meters)
Altitude Algorithm:
• Based on NOAA tables
Oxygen Exposure Limits:
• Based on NOAA tables
74

SPECIFICATIONS

OPERATIONAL MODES
• Activation/Diagnostic
• Surface -
• Temperature/Date/Time
• FO2 Set Point
• Pre Dive Planning Sequence
• Time to Fly/Desaturate
• Dive Log (Date/Nitrogen/Oxygen)
• Set -
• Alternate (On/Off)
• Year, Month, Day
• Hour Format (12/24)
• Hour, Minute
• Sampling Rate
• Units (Imperial/Metric)
• FO2 Default (On/Off)
• External Access (EA)
• No Decompression Dive - Main
• Secondary
• Alternate (Large Format)
• Decompression Dive -Main
• Secondary
• Alternate (Large Format)
• Violation (conditional, delayed, & immediate)
• Gauge
• High PO2
• High O2
• Backlight (Oceanglo ® /SmartGlo™)

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DATA PLUS and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

This manual is also suitable for:

Data plus 2

Table of Contents