Page 1
PRO PLUS 2 dive computer operating manual...
Page 2
The programs within the Pro Plus 2 simulate the absorption of nitrogen into the body by using a mathematical model. This model is merely a way to apply a limited set of data to a large range of experiences. The Pro Plus 2 dive computer Still, using the Pro Plus 2, just model is based upon the latest research and experiments in decompression theory.
Page 41
TO SET - BACKLIGHT DURATION 15 more times. Dura- tion...
Page 42
TO SET - PC SAMPLING RATE NOTE: Sampling Rate is the interval at which data samples are recorded during a dive for subse- quent download to the PC program. This setting has no effect on displayed data or data in the unit's viewable Log.
Page 43
TO SET - USER SET DIGITAL GAUGE MODE NOTE: Once a dive is made with this feature set ON, the setting will be locked ON for 24 hours after the dive. Set Digital Gauge Mode will not appear as a selec- tion during that 24 hour period.
TO SET - WATER ACTIVATION WARNING: If this feature is set for OFF, the Pro Plus 2 must be manually activated prior to commencing a dive. 18 more times...
Page 46
Oceanic strongly recommends that you review the Pre Dive Planning Sequence (PDPS) prior to every dive to help you plan your dive as required to avoid exceeding no decompression or oxygen exposure limits.
Page 47
To access the Pre Dive Planning Sequence FEET 1 time FEET...
Page 57
(Fig. 60) f you ascend shallower than a Required Decompression Ceiling Stop Depth DECO FEET Penalty Time...
Page 58
(Fig. 61) DECO FEET If you remain above the Required Ceiling Stop Depth for more than 5 minutes,...
Page 59
(Fig. 62) DECO FEET If the Decompression obligation requires a Ceiling Stop Depth between 60 feet (18 meters) and 70 feet (21 meters), FEET (Fig. 63) If you descend deeper than 330 feet (99.9 meters),...
Page 61
Immediate Violation Mode Gauge Mode This condition is a Permanent Violation, and in the DECO event that a dive is made during the 24 hour pe- riod, a full 24 hour surface interval must then be served before all functions are restored. Responsible...
Page 62
FEET 1.40 ATA, or 0.2 ATA less than the PO2 Alarm set point (a user setting); 1.60 ATA or the PO2 Alarm set point (a user setting), FEET...
Page 63
The O2 Bar Graph Caution Zone Use it as a visual reference to place a wider margin of protection between you and the Limits. FEET (Danger) Zone...
Page 71
To access the Log Mode and view the First Screen 4 times To view the Second Screen of the Log (Nitrogen data) 1 time FEET...
Page 72
To view the Third Screen of the Log (Oxygen data) 1 time To access the first screen of the previous dive's Log 1 time To access other modes or enter settings -...
Page 74
® Prior to attempting to download data from your Pro Plus 2, refer to the instructions provided in the User Manual that is incorporated into the CD for the download package. Refer to page 28 of this manual for instructions...