Gas Pressure Sdjustment - Cannon CANTIB User Instructions

Inbuilt models
Table of Contents

Advertisement

Gas pressure
adjustment
16
25.Switch the top two control buttons to "Full On" position as indi-
cated in figure 29(a) and using a ring spanner, as per figure
29(b), adjust the pressure to 1kPa for Natural gas or 2.65 kPa
for LPG. (Turn clockwise to increase pressure and anticlockwise
to decrease pressure).
29
26.Switch the stop button back to "Low Flame' position as indi-
cated in figure 30(a), retain spanner in position and using a
screwdriver as per figure 30(b) adjust the central screw control
to give a pressure reading of 0.3 kPa for Natural Gas and 1.1
kPa for LPG. (Turn clock-wise to increase pressure and anti-
clockwise to decrease pressure).
30
27.Switch burners off and remove the manometer tube. Tighten
pressure test point by turning the captive screw fully clockwise.
Replace plastic cap. Ensure the little lug is positioned towards
lower right hand side to clear the control.
28. Refit the lower front cover, making sure not to damage the
power cord.
29. Follow User Instructions to turn on heater.
Important:
To achieve the correct visual flame effect:
On Propane the gas pressure must be set at 2.65 kPa with
burner operating on maximum setting.
On Natural Gas the gas pressure must be set at 1.0 kPa.