If the flame is unstable:
❍ Check that the burner is located correctly.
❍ Check that the glass front is located correctly and is against the
sealing rope.
❍ Check that the gas pressure is correctly adjusted.
If the heater still does not operate to specification refer to the trouble-
shooting chart on pages 22 & 23, or contact Sampford IXL in your
state.
Pressures for 'Burner full on' and 'Burner low flame' are factory
set, however if pressures need to be checked or adjusted follow the
procedures described below and on the next two pages.
20
16. To check control outlet pressure at burner 'Full on" and 'Low Flame"
positions, remove the plastic cap from the regulator adjustment loca-
tion as indicated in figures 21 (a) & (b).
21

Gas pressure point

17. The pressure point is closed with a captive screw. Turn screw 6 revo-
lutions anticlockwise to open the pressure point as indicated on figure
22 (a) and place manometer tube over the test point as per figure 22
(b).
22
13