Gas Control; Gas Pressure Point - Cannon CANTIB User Instructions

Inbuilt models
Table of Contents

Advertisement

Gas control

Gas pressure point

23.Gas control layout is as indicated in figure 26.
Pressures for 'Burner full on' and 'Burner low flame' are factory
set, however if pressures need to be checked or adjusted fol-
low the procedures described below and on the next two pages.
26
To check control outlet pressure at burner 'Full on" and 'Low
Flame" positions remove the plastic cap from the regulator ad-
justment location as indicated in figures 27 (a) & (b).
27
24 The pressure point is closed with a captive screw. Turn screw 6
revolution anticlockwise to open the pressure point as indicated
on figure 28 (a) and place manometer tube over the test point
as per figure 28 (b).
28
15